SNG timer

SNG timer
Product Detailed
Related Categories:Timers
Related Product Searches:SNG timer,High Quality,timer, digital timer,SNG
SNG timer clock accuracy: class 0.005 F.S Power supply:AC220V 7A time range:0-9999s 0-9999M SIZE: 48*48*90MM; 44*44mm

SNG intelligent time relay is intelligent double row four-LED display meter, it is operated with three-keys, have the function of single setting,double setting time. Parameters set isfast, symbols display is simple. The meter adopts the imported super anti-chip design, quality is reliable.

Technical specification:

Clock accuracy: class 0.005%F.SRelay output contact capacity: AC220V 5A (resistance load)Work power : AC85~242V 50/60Hz Time range:0~9999second or 0~9999minuteWork environment: temperature 0~50°C, humidity≤85%RH without corrode and strong electric radiationOverall size and installation hole (mm): 48×48×90 ;   44×44

Operation the instrument

Electrify after taking into the power and control circuit according to the connection scheme,and then the instrument start testing itself for 1 second.

Connect the reset terminal, the meter start timing, timing is operated on accordance with the meter parameters; disconnect the reset terminal, the meter time clears. When the OUT indicator of the panel is on, the meter terminals 7,8 have output.

Press the SET key 3S enter into the setting area, the meter will display the parameter code 1~4 in the window at the upper row and display the parameter data at the lower row. In this time press the Δ or ν key to adjust the parameter data, then press the SET key to preserve. If within 10 seconds do not press every key then it will automatically to preserve the data and withdraw the setting.

Parameter code

Series

Attention

Name

Manual

Setting range

1

tE1

Timing time 1

——

0~9999

2

tE2

Timing time 2

It has only double time working

0~9999

3

Int

The meter working method

0. attract gather time when delay

1. separate time when delay

2. Double time circulates moves

T1 is separates time,T2 is attracts gathers time

3. Double time not circulates moves

T1 is separates time, T2 is attracts gathers time

4. Double time circulates moves

T1 is attracts gathers time, T2 is separates time

0~4

4

UPt

Time unit and time hours method

0: count down, unit is second

1: clockwise, unit is second

2: count down, unit is minute

3: clockwise, unit is minute

0~3

SNG timer