JSS48-70(JSS20-482*99HMS) Digital Timer is the type of prolonging the connection with the electricity and one of the newly control instruments during these years,The relay adopt CPU and 4-LED display,it applies component AC 60HZ,operating voltage is 220V ,and control the circuit during the scheduled time.
Technical Index
1. Display method4-LED display directly the time
2. Distinguish ability 1s1min1h
3. Control Range1S99H
4. Setting methodSecondSMinuteMhourHcan set by selection freely
5. Power supplyAC85~242V/24V 50Hz
6. Power consumption3W
7. Output trigger capacity:AC220V 3A(resistance negative carry)
8. Working circumstancetemperature 050,humidity85%RH without corrosive gas situation.
Setting
According to the dimension open a hole in the installation hole, install the time relay into the installation hole with a frame.
Overall dimensionmm48×48×125 Hole sizemm45×45
Method to use
1. As the relay has the memorial function,it should be valid till setting the time before opening the power The discontinuous time of the relay’s repeat starting should be more than or be equal to 0.5 second.
2.Set all the switches,open the power ,it displays and start timing until the scheduled time. As the contactchanges,the time control is over.
3.open the power ,a couple of LED at left side start timing ,the time relay's 'general' , 'ower' is connect, 'general', 'higher' is disconnect,until time out of the scheduled time at left side,the time relay's 'general', 'lower' is disconnect, 'general', 'higher' is connect;at one time ,a couple of LED at right side start timing,until time out of the scheduled time at right side,the time relay's 'general', 'lower' is connect, 'general', 'higher' disconnect; at one time left side start timing again,circle control like this.
4.Reposition function: Any time to switch on reposition terminal ,the relay will return to the original state.
5.Pause function: during the work time ,switch on the pause terminal,the timing will pause and displays the current time and prompt sign "P". After then start timing again it can accumulatetime.
6.During the strong electric power environment and the long wire of reposition terminal, and pause terminal ,please use shield lead.
7.Don't input voltage to Reposition terminal and pause terminal in order to avoid damaging product.
timer